Product Overview
Optional 4~20mA transmission (with HART communication), pulse output, high and low limit alarm output function, etc. The type of intelligent signal transmitter has high precision and reliability, and also high price performance, parameter standardization online and failure protection, etc.
Features
● Suitable for small bore and low flow media
● Long life, reliable and low maintenance
● Low requirements for straight pipe sections
● Large LCD display, can display instantaneous flow and cumulative flow at the same time
● Backlight
● All-metal structure, can withstand high temperature, high pressure and strong corrosive media
● Data recovery, data backup and power failure protection functions
Product Details
Configuration
Medium |
___________________________ | |
Medium Temperature |
□-40~250°C |
□-40~450°C |
Measuring Range |
___________________________ | |
Liquid Contact Material |
□Stainless steel304 | |
□Stainless steel316L | ||
□PVC | ||
□PP | ||
□PTFE | ||
Mounting Position |
□Top |
□Side |
Mounting Type |
□Flange__________ |
□Thread__________ |
Output |
□Flap Local display;□Limit alarm;□Transmitter |
|
Output Signal |
□4-20mA; □RS485; □Modbus |
|
Option |
□Drain valve |
|
Explosion-proof |
___________________________ |
Applications and Specifications
Liquid: water, oil
Medium |
liquid |
Medium Temperature |
-40~450°C |
Medium Viscosity |
≤ 0.15 Pa.s |
Medium Pressure |
≤ 25mPa |
Medium Density |
≥ 0.5g/m³ |
Measuring Accuracy |
± 10mm |
Liquid Contact Material |
Stainless steel; PVC; PP; PTFE |
Mounting Position |
Top; Side |
Mounting Type |
Flange; Thread |
Output |
Flap Local display; Limit alarm; Transmitter |
Output Signal |
4-20mA; RS485; Modbus |
Explosion-proof |
ExdIICT6 |
Technical Parameter
1. Flange size and sealing surface: DN15, DN20, DN25, DN40, etc.
2. Body material: 304 316 316L PP plastic
3. Measuring range (mm): 299~8999
4. Medium density (g/cm3): 0.49~1.99
5. Medium viscosity: ≤0.019Pa.S
6. Working temperature ℃: -39.9~349.99
7. Pressure rating (MPa): ≤31.99
8. Measurement accuracy (mm): ≤±4.99
9. Installation method: side-mounted
10. Protection level: IP64.99
11. Explosion-proof grade: ibⅡCT4 (intrinsically safe type), dⅡBT4 (explosion-proof type)
12. Transmission mode: 4~20mA
Product detail pictures:
Related Product Guide:
We also provide item sourcing and flight consolidation solutions. We have now our very own manufacturing facility and sourcing place of work. We could provide you with nearly every kind of merchandise associated to our merchandise variety for China OEM Acid Level Indicator - JEL-100 Series Magnetic Flap Flow Meter – , The product will supply to all over the world, such as: Muscat, Iran, Spain, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to for you of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we are going to have a bright prospect and to be distributed all over the world in the years to come.