Visible LCD digital Display Current/total flow
IP65 IPS67 ABS/Metal Instrument enclosure
ABS electrical interface Waterproof Dustproof
Fully automatic SMT chip circuit Stable and durable
Clamp-on type/ Insertion type
Product Description
JEF-200 ultrasonic flowmeter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clamp-on type, which will provide benefits of non-fouling operation and easy installation.
Ultrasonic flow meters use sound waves as a reliable, accurate and maintenance free method to measure the velocity of a fluid from which the volumetric flow rate can be calculated. They feature no moving parts making them more reliable and accurate while providing maintenance-free operation. Since ultrasonic signals can also penetrate solid materials, the transducers can be mounted onto the outside of the pipe offering completely non-invasive measurement eliminating chemical compatibility issues, pressure restrictions, and pressure loss.
Swimming against the flow requires more power and more time than swimming with the flow. This simple fact is the basis for ultrasonic flow measurement according to the “differential transit time” method: This method uses two sensors, set opposite each other in the measuring tube. Each sensor can alternately transmit and receive ultrasonic signals, while simultaneously measuring the signal transit time.
As soon as the fluid in the tube starts to flow, the signals are accelerated in the direction of flow but delayed in the opposite direction. The differential transit time, measured by the two sensors, is directly proportional to the flow rate.
Product Details
JEF-201 Wall-mounted plastic case type
JEF-202 Wall-mounted metal case type
JEF-203 Module type
JEF-204 Portable handy type
Type |
JEF-201 Wall-mounted plastic case type; JEF-202 Wall-mounted metal case type; JEF-203 Module type; JEF-204 Portable handy type | |
Transducer |
Clamp on | TS- 2TM- 1; TL- 1 |
High-temp Clamp on | TS-2-HT; TM-1-HT; TL-1-HT | |
Insertion | TC- 1T; C- 2 | |
Pipe | G3; G2; G1 | |
Nominal Diameter |
DN __________mm | |
Pipe Material |
0-Carbon Steel; 1-Stainless steel; 2-Cast iron; 3-Copper; 4-Cement pipe; 5-Aluminum; 6-PVC; 7-Glass steel | |
Cable length |
mm | |
Temperature Transducer |
CT- 1; TCT- 1; PCT- 1; SCT- 1 | |
SD Card |
0-YES1-NO |
Example: JEF201-TM-1-DN300-0- 10m- PCT- 1+0
PS: Standard confirguration = Wall-mounted plastic case type (convertor)+ TM- 1 (transducer)+ 5 M cable + PCT- 1(temperature transducer)+ SD Card
Benefits and Application
● Measurement independent of pressure, density, temperature, conductivity and viscosity (for homogeneous fluids)
● Free pipe cross-section, no pressure loss
● No moving parts, minimum maintenance and upkeep
● Long service life, no abrasion or corrosion from the fluid
● In-line or clamp-on design for stationary or temporary flow measurements
● Ultrasonic flow meter is high reliability of flow meter, widely used in petroleum, chemical industry, food, electricity, water supply and drainage, etc.
Features
● High Reliability: Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
● Wide measuring range: Several types transducer for selection, pipe size from Dn15mm to Dn6000mm.
● High Reliability: Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability.
● Strong Anti-interference: Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.
● Powerful Recording Function: Automatically record the following data, The totalizer data of the last 512 days/128 months/10 years, The time and corresponding flow rate of the last 64 times of power on and off events, The working status of the last 32 days.
● Support Heat Measurement: Connect the temperature transducer , can finish the heat/energy measurement.
● Support SD card Memory: Optional SD card.
Optional Transducers
Types |
Picture |
Spec. |
Model |
Measurement Range |
Temperature |
Dimension |
Clamp on |
|
Small Size |
TS- 2 |
DN15~ DN100 |
-30~ 90℃ |
64×39×44mm |
|
Medium Size |
TM- 1 |
DN50~ DN700 |
-30~ 90℃ |
97×54×53mm |
|
|
Large Size |
TL- 1 |
DN300~ DN6000 |
-30~ 90℃ |
45×25×32mm |
|
High temp Clamp on |
|
Small Size |
TS-2-HT |
DN15~ DN100 |
-30~ 160℃ |
64×39×44mm |
|
Medium Size |
TM-1-HT |
DN50~ DN700 |
-30~ 160℃ |
97×54×53mm |
|
|
Large Size |
TL-1-HT |
DN300~ DN6000 |
-30~ 160℃ |
190×80×55mm |
|
Insertion |
|
Standard |
TC- 1 |
DN80~ DN6000 |
-30~ 160℃ |
335×80×55mm |
|
Lengthen |
TC- 2 |
DN80~ DN6000 |
-30~ 160℃ |
64×39×44mm |
|
Pipe |
|
Π type |
G3 |
DN15~ DN25 |
-30~ 160℃ |
|
|
Standard |
G2 |
DN32/ DN40 |
-30~ 160℃ |
||
Standard |
G1 |
DN50~ DN6000 |
-30~ 160℃ |
Optional Temperature Transducers
Picture |
Specification |
Model |
Meas. Range |
Temperature |
Cut of water |
Accuracy |
|
Clamp on temperature Transducer Pt100 |
CT- 1 |
≥DN50 |
- 40~ 160℃ |
No |
100℃±0. 8℃ |
Insertion temperature Transducer Pt100 |
TCT- 1 |
≥DN50 |
- 40~ 160℃ |
Yes |
||
Insertion Pt100 Installation with pressure |
PCT- 1 |
≥DN50 |
- 40~ 160℃ |
No |
||
Insertion Pt100 Small pipe diameter |
SCT- 1 |
<DN50 |
- 40~ 160℃ |
Yes |
Specifications
Measuring Medium | Type of Liquid | Single liquid can transmit sound wave, Water (hot water, chilled water, city water, sea water, waste water, etc.), Sewage with small particle content; Oil ( crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals ( alcohol, etc.); Plant effluent; Beverage, Ultra- pure liquids |
Temperature | - 30~ 160℃ | |
Turbidity | No more than 10000ppm and less bubble | |
Flowrate | 0~±7m/ s | |
Accuracy | ±1% | |
Display | 2×20 character LCD with backlight, support Chinese, English and Italy | |
Caliber range | DN15-200 | |
Signal Output | 1 way 4~ 20mA output, electric resistance 0~ 1K | |
1 way OCT pulse output( Pulse width 6 ~ 1000 ms, 200 ms default) | ||
1 way Relay output | ||
Signal Input | 3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as temperature, press and liquid level | |
Connect the temperature transducer Pt100, can finish the heat/energy measurement | ||
Data Interface | Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS | |
Pipe Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed |
Pipe Diameter | 15~ 6000mm | |
Straight Pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump | |
Working Environment | Temperature | Convertor:- 20~ 60℃;Flow Transducer:- 30~ 160℃ |
Humidity | Convertor: 85% RH;Flow Transducer:can measure under water, water depth≤2m(tansducer sealed glue) | |
Power Supply | DC8~ 36V or AC85~ 264V(optional) | |
Power | 1. 5W | |
Dimension | 205*154*70cm(convertor) |
Optional SD card
The SD card (most expanded to 2GB) can achieve data storing, reading and processing issues by replacing manual writing or no-paper recording instrument.
In addition, the SD card measurements data can be adopted by our company’s “JEF Flow data analysis & statistic” Software which includes tabulation, statistical, data analysis, printing reports, production flow curve and other functions.
Product detail pictures:
Related Product Guide:
Our well-equipped facilities and great good quality regulate throughout all stages of manufacturing enables us to guarantee total buyer gratification for Factory selling Portable Water Flow Meter - JEF-200 Ultrasonic Flowmeter for water and liquid – , The product will supply to all over the world, such as: Paraguay, Singapore, Algeria, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.
By Prima from Slovak Republic - 2018.06.05 13:10
The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
By Donna from Algeria - 2018.12.11 11:26