Factory source Turbine Air Flow Meter - JEF-300 Electromagnetic Flowmeter –
Factory source Turbine Air Flow Meter - JEF-300 Electromagnetic Flowmeter – Detail:
Product Details
Application
● General conductive liquid
● Strong corrosive liquids such as strong acid and alkali
● Uniform liquid-solid two-phase suspension liquid such as slurry, pulp, and paper pulp
Features
● Digital processing, strong anti-interference ability, reliable measurement, high precision, flow measurement range can reach 150:1;
● Ultra-low EMI switching power supply, the large voltage range of suitable power supply, good anti-EMI performance;
● Use 16-bit embedded microprocessor, with fast operation speed, high precision, and programmable low-frequency rectangular wave excitation, improving the stability of flow measurement and low power consumption;
● Use SMD parts and surface mount (SMT) technology, high circuit reliability;
● No moving parts in the pipe, no flow blocking parts, and there is almost no additional pressure loss in the measurement;
● It can modify the range of online on-site according to the actual needs of users;
● The measurement results are independent of the physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity;
● High-definition backlit LCD display, full Chinese menu operation, easy to use, easy to operate, easy to learn and understand;
● With digital communication signal output such as RS485, RS232, Hart, and Modbus (optional);
● With self-test and self-diagnosis function;
● With hourly total recording function, recording the total amount of flow in hours, suitable for time-sharing measurement (optional);
● There are three Integrators, which can display the forward accumulation amount, the reverse accumulation amount, and the difference calculation amount respectively. There is an internal power-down clock, which can record 16 power-down times. (optional);
● With an infrared handheld operator, with a 115KHZ communication rate, it can operate all functions of the converter remotely without contact (optional).
Product Portfolio
Specifications
Measuring Medium |
Conductive liquids containing impuritiesStrong corrosive liquids such as acid, alkali, seawater | ||
Accuracy |
士0.5%R | 士1.0%R | |
Repeatability |
0.1% | 0.2 | |
Range ratio |
20:1 |
||
Flow velocity |
0.5- 10m/s |
||
Type |
Material | Carbon steel | |
Stainless steel | |||
Shape | Integrated type | ||
Split type | |||
Connection | Flange type | ||
Clamp-on type | |||
Thread type | |||
Plug-in type | |||
Lining Material |
Rubber | CR | |
PU | |||
PTFE | PTFE | ||
FEP | |||
PFA | |||
Nominal diameter |
Rubber | DN 40- DN 2000 | |
PTFE | DN 10 – DN 600 | ||
Electrode |
316L | ||
Hastelloy B | |||
Hastelloy C | |||
Ti | |||
Ta | |||
Pt | |||
Tungsten Carbide | |||
Signal Input |
4~ 20mA | ||
4- 20 mA/1 – 5 KHz | |||
Data Interface |
RS-232, RS485, HART, Modbus,Profibus | ||
Working Environment
|
Medium temperature | Rubber : -20°C ~ +60°C | |
Rubber(high-temperature) : -20°C ~ +90°C | |||
PTFE : -30°C ~ +120°C | |||
PTFE(high-temperature) : -20°C ~ +160°C | |||
Environment condition | Temperature:-25°C ~ +60°CHumidity: 5% ~ 95 % | ||
Power Supply |
DC8~ 36V or AC85~ 264V(optional) | ||
Protection |
IP65 IP68 |
Optional Lining Material
Material |
Spec. |
Medium |
Medium Temp. |
Pipe Diameter |
|
Rubber |
CR |
Abrasion resistance:good Corrosion resistance:normal |
water, seawater |
<60°C |
DN50-2000 |
PU |
Abrasion resistance:excellent Corrosion resistance:bad |
slurry, pulp, and paper pulp |
<60°C |
DN25-500 |
|
Fluorine Plastic |
PTFE |
Corrosion resistance:excellent |
strong acid and alkali |
<120°C |
DN25-1600 |
FEP |
Corrosion resistance:excellent |
strong acid and alkali |
<120°C |
DN10-200 |
|
PFA |
Corrosion resistance:excellent |
strong acid and alkali |
<160°C |
DN10-300 |
Optional Electrode
Material |
Specification |
316L |
1 Domestic water, industrial water, raw water, well water, urban sewage; 2 Weak corrosive acids, bases and salt solutions. |
Hastelloy B |
Suitable: 1 Hydrochloric acid (less than 10% concentration) non-oxidizing acid; 2 Sodium hydroxide (concentration less than 50%), ammonium hydroxide alkali solution; 3 Phosphoric acid, organic acid; Not suitable: 1 Nitric acid. |
Hastelloy C |
Suitable:1 Mixed acid and mixed liquid of complex acid and sulfuric acid; 2 Oxidizing salts such as Fe+++, Cu++, seawater; 3 Phosphoric acid, organic acid; Not suitable:1 Hydrochloric acid. |
Ti |
Suitable:1 Chloride(chloride / magnesium / aluminum / calcium / ammonium / iron, etc.); 2 Sodium salt, potassium salt, ammonium salt, hypoaluminate, seawater; 3 Potassium hydroxide whose concentration is less than 50%, and the potassium hydroxide and barium hydroxide salt solutions; Not suitable: Reducing acids such as hydrochloric acid, sulfuric acid, hydrogen phosphate, krypton acid, etc. |
Ta |
Suitable: 1 Hydrochloric acid (less than 40% concentration), dilute sulfuric acid and concentrated sulfuric acid (excluding oleum); 2 Chlorine dioxide, ferric chloride, hypochlorous acid, sodium oxide, acetic acid, etc. 3 Oxidizing acids such as nitric acid (including fuming nitric acid), aqua regia at a temperature lower than 80°C; Not suitable: Alkali, Hydrogen Nitrogen Acid. |
Pt |
Suitable:All acid-base and salt solutions (including fuming sulfuric acid, fuming nitric acid) aqua regia, ammonium salt; Not suitable: Alkali, Hydrogen Nitrogen Acid. |
Tungsten Carbide |
Suitable:Pulp, sewage; Not suitable:Inorganic acids, organic acids, chlorides. |
Configuration
Type | Shape | JEF-301 Integrated type |
JEF-302 Split type | ||
JEF-303 Plug-in type | ||
Material | 1 Carbon steel | |
2 Stainless steel | ||
Connection | F Flange type | |
C Clamp-on type | ||
T Thread type | ||
Lining Material | Rubber | 1 CR |
2 PU | ||
PTFE | 3 PTFE | |
4 FEP | ||
5 PFA | ||
Nominal diameter | DN mm | |
Electrode | SS 316L | |
HB Hastelloy B | ||
HC Hastelloy C | ||
Ti | ||
Ta | ||
Pt | ||
TC Tungsten Carbide | ||
Signal Input | A 4~ 20mA | |
B 4- 20 mA/1 – 5 KHz | ||
Data Interface | A RS-232 B RS485 H HART M Modbus P Profibus |
Example: JEF3011F-3-DN100-Ta- A – B
PS: Standard configuration = Integrated flange carbon-steel electromagnetic flowmeter + PFFE material lining + DN100mm + Ta electrode+4~20Ma output+RS485
Product detail pictures:
Related Product Guide:
No matter new buyer or old purchaser, We believe in long expression and trusted relationship for Factory source Turbine Air Flow Meter - JEF-300 Electromagnetic Flowmeter – , The product will supply to all over the world, such as: Morocco, Congo, Algeria, Meanwhile, we're building up and consummating triangle market & strategic cooperation in order to achieve a multi-win trade supply chain to expand our market vertically and horizontally for a brighter prospects. development. Our philosophy is to create cost-effective products and solutions, promote perfect services, cooperate for long-term and mutual benefits, firm a in depth mode of excellent suppliers system and marketing agents, brand strategic cooperation sales system.
By Pearl Permewan from Slovak Republic - 2018.05.13 17:00
The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
By Megan from Azerbaijan - 2017.01.28 18:53