New Delivery for Sanitary Type Turbine Flowmeter - JEF-400 Series Vortex Folwmeter –
New Delivery for Sanitary Type Turbine Flowmeter - JEF-400 Series Vortex Folwmeter – Detail:
Product Description
Vortex flowmeters are used in numerous branches of industry to measure the volume flow of liquids, gases and steam. Applications in the chemicals and petrochemicals industries, for example, in power generation and heat-supply systems involve widely differing fluids: saturated steam, superheated steam, compressed air, nitrogen, liquefied gases, flue gases, carbon dioxide, fully demineralized water, solvents, heat-transfer oils, boiler feedwater, condensate, etc.
Product Details
Application
Steam, Air, Compressed air, Biogas, Methane gas, CO2, Oxygen(O2), Helium gas, LNG, N2, KEROSENE, Methane gas, Water.
Features
● In-line flange process connection vortex flow meter, sensor size up to 12 inch
● Powerful and easy configuration vortex flow transmitter
● Easy installation
● All stainless steel vortex flowmeter
● Little pressure loss
● Large measuring range and high accuracy
● Accurate flow measurement is not affected by the fluids density, pressure, temperature, also viscosity
● No moving mechanical parts inside the vortex flow sensor, so high reliability and low maintenance
● Low price cost flow meter
Product Portfolio
Specifications
Measuring Medium |
Gas, Liquid, Steam | |
Accuracy |
Liquid | ±1% |
Gas Steam | ±1.5%~±1% | |
Range ratio |
1:10 1:15 1:20 |
|
Nominal diameter |
DN15 DN20 DN25 DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300 |
|
Type |
Material | 304L SS |
316L SS | ||
Shape | Integrated type (Local display) | |
Split type | ||
Connection | Flange type | |
Clamp-on type | ||
Plug-in type | ||
Signal Input |
Pulse signal, 4- 20 mA | |
Data Interface |
RS-232, RS485, HART, Modbus,Profibus | |
Working Environment
|
Medium temperature | -40°C ~ +250°C |
-40°C ~ +320°C | ||
Environment condition | Temperature: -20°C ~ +60°CHumidity: 5% ~ 95 % | |
Power Supply |
Battery, 24V | |
Protection |
IP65, IP68 | |
Explosion-proof |
ExiaIICT5, ExdIIBT6 |
Application Range-Flange type
Diameter |
Liquid medium Range(m³/h) |
Gas medium Range(m³/h) |
Connection |
Pressure Mpa |
DN15 |
1.2-6.2 |
5-25 |
Flange |
2.5/1.6 |
DN20 |
1.5-10 |
8-50 |
Flange |
2.5/1.6 |
DN25 |
1.6-16 |
10-70 |
Flange |
2.5/1.6 |
DN32 |
1.9-19 |
15-150 |
Flange |
2.5/1.6 |
DN40 |
2.5-26 |
22-220 |
Flange |
2.5/1.6 |
DN50 |
3.5-38 |
36-320 |
Flange |
2.5/1.6 |
DN65 |
6.2-65 |
50-480 |
Flange |
2.5/1.6 |
DN80 |
10-100 |
70-640 |
Flange |
2.5/1.6 |
DN100 |
15-150 |
130-1100 |
Flange |
2.5/1.6 |
DN125 |
25-250 |
200-1700 |
Flange |
1.6/1.6 |
DN150 |
36-380 |
280-2240 |
Flange |
1.6/1.6 |
DN200 |
62-650 |
580-4960 |
Flange |
1.6/1.6 |
DN250 |
140-1400 |
970-8000 |
Flange |
1.6/1.6 |
DN300 |
200-2000 |
1380-11000 |
Flange |
1.6/1.6 |
Application Range- Plug-in type
Diameter |
Measuring Range(m³/h) |
Diameter |
Measuring Range(m³/h) |
||
Liquid |
Gas |
Liquid |
Gas |
||
DN250 |
80-1150 |
1060-10600 |
DN900 |
970-12000 |
13000-130000 |
DN300 |
13-1400 |
1540-15400 |
DN1000 |
1130-16900 |
17000-170000 |
DN400 |
180-2700 |
2700-27000 |
DN1100 |
1450-18000 |
19000-190000 |
DN500 |
280-4200 |
4240-42400 |
DN1200 |
1630-24400 |
24400-244000 |
DN600 |
410-6100 |
6100-61000 |
DN1300 |
2020-25300 |
27000-270000 |
DN700 |
580-7300 |
7800-78000 |
DN1400 |
2350-29500 |
31000-310000 |
DN800 |
720-10800 |
10850-108500 |
DN1500 |
2550-38000 |
38200-382000 |
Configuration
Type | Shape | JEF-401 Integrated type (Local display) | |||||||
JEF-402 Split type | |||||||||
Material | 1 304L | ||||||||
2 316L | |||||||||
Connection | F Flange type | ||||||||
C Clamp-on type | |||||||||
P Plug-in type | |||||||||
Compensation | □N No | T Temp. | P Pressure | TP Both | |||||
Medium | □1 Liquid | 2 Gas | 3 Compressed air | 4 Steam | |||||
Nominal diameter | DN mm | ||||||||
Power | 1 Battery | 2 24V | |||||||
Signal output | 1 No | 1 Pulse signal | 2 4-20mA | ||||||
Data Interface | A RS-232 B RS485 H HARTM Modbus P Profibus other | ||||||||
EX grade | 1 No | 2 ExdIIBT6 | other |
Example: JEF4021F-TP-1DN100-1-2-B-2
PS: Standard configuration = 316L Integrated flange type vortex flowmeter +
Temperature & pressure compensation + Liquid DN100mm + Battery+4-20Ma+RS-485+ ExdIIBT6
Product detail pictures:
Related Product Guide:
The key to our success is "Good Product or service High quality, Reasonable Rate and Efficient Service" for New Delivery for Sanitary Type Turbine Flowmeter - JEF-400 Series Vortex Folwmeter – , The product will supply to all over the world, such as: America, Jakarta, Liverpool, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world
By Ina from Brazil - 2017.05.02 18:28
This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
By Ruby from Ethiopia - 2017.05.02 11:33