Special Design for Dp Cell Level Measurement - JEL-100 Series Magnetic Flap Flow Meter –
Special Design for Dp Cell Level Measurement - JEL-100 Series Magnetic Flap Flow Meter – Detail:
Datasheet
Product Overview
Optional 4~20mA transmission (with HART communication), pulse output, high and low limit alarm output function, etc. The type of intelligent signal transmitter has high precision and reliability, and also high price performance, parameter standardization online and failure protection, etc.
Features
● Suitable for small bore and low flow media
● Long life, reliable and low maintenance
● Low requirements for straight pipe sections
● Large LCD display, can display instantaneous flow and cumulative flow at the same time
● Backlight
● All-metal structure, can withstand high temperature, high pressure and strong corrosive media
● Data recovery, data backup and power failure protection functions
Product Details
Configuration
Medium |
___________________________ | |
Medium Temperature |
□-40~250°C |
□-40~450°C |
Measuring Range |
___________________________ | |
Liquid Contact Material |
□Stainless steel304 | |
□Stainless steel316L | ||
□PVC | ||
□PP | ||
□PTFE | ||
Mounting Position |
□Top |
□Side |
Mounting Type |
□Flange__________ |
□Thread__________ |
Output |
□Flap Local display;□Limit alarm;□Transmitter |
|
Output Signal |
□4-20mA; □RS485; □Modbus |
|
Option |
□Drain valve |
|
Explosion-proof |
___________________________ |
Applications and Specifications
Liquid: water, oil
Medium |
liquid |
Medium Temperature |
-40~450°C |
Medium Viscosity |
≤ 0.15 Pa.s |
Medium Pressure |
≤ 25mPa |
Medium Density |
≥ 0.5g/m³ |
Measuring Accuracy |
± 10mm |
Liquid Contact Material |
Stainless steel; PVC; PP; PTFE |
Mounting Position |
Top; Side |
Mounting Type |
Flange; Thread |
Output |
Flap Local display; Limit alarm; Transmitter |
Output Signal |
4-20mA; RS485; Modbus |
Explosion-proof |
ExdIICT6 |
Technical Parameter
1. Flange size and sealing surface: DN15, DN20, DN25, DN40, etc.
2. Body material: 304 316 316L PP plastic
3. Measuring range (mm): 299~8999
4. Medium density (g/cm3): 0.49~1.99
5. Medium viscosity: ≤0.019Pa.S
6. Working temperature ℃: -39.9~349.99
7. Pressure rating (MPa): ≤31.99
8. Measurement accuracy (mm): ≤±4.99
9. Installation method: side-mounted
10. Protection level: IP64.99
11. Explosion-proof grade: ibⅡCT4 (intrinsically safe type), dⅡBT4 (explosion-proof type)
12. Transmission mode: 4~20mA
Product detail pictures:
Related Product Guide:
As for aggressive price ranges, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such high-quality at such price ranges we're the lowest around for Special Design for Dp Cell Level Measurement - JEL-100 Series Magnetic Flap Flow Meter – , The product will supply to all over the world, such as: Singapore, Egypt, Georgia, We have been committed to meet all your needs and solve any technical problems you may encounter with your industrial components. Our exceptional products and vast knowledge of technology makes us the preferred choice for our customers.
By Fay from Israel - 2018.05.15 10:52
We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
By Grace from New Zealand - 2017.03.08 14:45